University of Bergen
Inst. of Solid Earth Physics
Allé gt. 41, N-5007 Bergen, Norway

 

GECO TRIACQ RECORDING SYSTEM

Setup of CPU cards on Streamer Interface (SI) and Recording / Real-time Visualization (RTV)

Connect serial cable to COM A port on SI or RTV. Open terminal window, 'tip hardwire' command, reset CPU card on SI or RTV, interrupt autoboot (strike any key), press 'c' to configure, afterwards '@' to boot.

[Blank] means no entry.

Parameter Streamer Interface Recording / Real-time Visualization
boot device ln ln
processor number 0 0
host name hm-acqrc1 hm-acqrc1
file name /triacq/vw53/fre40/vxWorks /triacq/vw53/frc5ce/vxWorks
inet on ethetnet (e) 192.168.219.36:ffffff80 192.168.219.33:ffffff80
inet on backplane (b) [Blank] [Blank]
host inet (h) 192.168.219.39 192.168.219.39
gateway inet (g) [Blank] [Blank]
user (u) siuser siuser
ftp password [Blank] [Blank]
flags (f) 0x0 0x0
target name hm-acqsi1 hm-acqrtv1
startup script (s) /triacq/tri_etc/si1.script /triacq/tri_etc/rtv1.script
other [Blank] [Blank]

om, Sept. 15, 2002